LED colors and audibles indicate maintenance or troubleshooting need.
The meaning of LED colors is below.
The meaning of LED colors is below.
LED | Color and Action | Meaning and Troubleshooting |
---|---|---|
Disk1 or Disk2 | Green, Flickering | The Disk is being accessed. |
Disk1 or Disk2 | Red, Stable | The Disk1 or Disk2 failed. Replace the drive. |
Disk1 or Disk2 | Red, Flashing | Rebuilding RAID array is performed. Don't turn the unit off. Otherwise, restored data is lost. (Red and green flashing continues frequently because of disk access.) Estimated rebuilding time is 7 to 8 hours for 500GB model, 11 to 12 hours for 800GB. 1.0TB and 1.5TB model are more. |
Disk1 and Disk2 | Red, Stable on both | Replaced disk capacity is lower than original one. Unable to start rebuilding RAID. |
Beep Status: | ||
Beep Code | Meaning | |
Alternating continuous short beep then silence | Internal cooling fan is stopped. | |
Continuous beep | Hard disk unit temperature is too high. | |
Three second beep then silence | The Disk1 or Disk2 is failed. Replace the drive. |