[Answer ID: 11894]
What does the message on the LCD display indicate when the INFO LED is turned on? (TS-X series)
INFO LED will flash with orange to display the current status when changing the settings or formatting hard drives.
Examples of LCD |
Meaning |
Resolution |
|
I11 |
HDx Warning |
Bad sectors in Xth hard drive may reach the dangerous zone. |
Replace Xth hard drive. |
I12 |
Operation Mode |
RAID Degrade mode is running. |
- |
I13 |
RAID |
Formatting Xth RAID Array. |
- |
I14 |
RAID |
Checking Xth RAID Array. |
- |
I15 |
RAID |
Investigating the error status occurred in Xth RAID array. * During the investigation, transfer speed will be degraded. |
- |
I16 |
RAID |
Creating Xth RAID Array. |
- |
I17 |
RAID |
Resyncing Xth RAID Array. * While resyncing, the transfer speed will be degraded. |
- |
I18 |
RAID |
Rebuilding Xth RAID Array. * While rebuilding, the transfer speed will be degraded. |
- |
I19 |
RAID |
Deleting data completely by filling 0 into Xth RAID array. |
- |
I20 |
DISK |
Formatting Xth hard drive. |
- |
I21 |
DISK |
Checking Xth hard disk. |
- |
I22 |
DISK |
Deleting data in Xth hard drive. |
- |
I23 |
SYSTEM |
Initializing the system. |
- |
I25 |
SYSTEM |
Updating the TeraStation's firmware. * Do not turn off the TeraStation while updating. |
- |
I26 |
Web Setting |
Initializing web configuration. |
- |
I27 |
USB Diskx |
Checking Xth USB hard disk. |
- |
I28 |
USB Diskx |
Formatting Xth USB hard drive. |
- |
I31 |
Press FuncSW |
This message is displayed when restructure RAID by pressing a function switch after replacing the hard drive. |
Press a function switch for rebuilding RAID array. |
I32 |
Set From Web |
This is displayed when RAID needs to be restructured on the Web Admin interface or formatted after replacing the hard drive. |
Rebuild RAID array or format on the web admin interface. |